Battery Voltage Chart

Sungold Battery Voltage Chart

his guide gives you a practical battery voltage chart for LiFePO4 and AGM/Gel in 12V/24V/48V, shows you how to measure voltage the right way, how to roughly estimate state of charge (SOC), and how to set charging parameters. We’ll also map these numbers into real-world RV and off-grid system design—using Sungold’s anti-shade and lightweight flexible panels to keep charging stable in partial shade, tight roof spaces, and curved surfaces.

Why Voltage Is Handy—but Can Mislead (Especially with LiFePO4)

  • Easy to read: A basic multimeter gives you fast feedback, even during outages.

  • But LiFePO4 has a flat voltage curve: Voltage doesn’t change much across a big chunk of capacity, so SOC by voltage is approximate at best.

  • Context matters: If you measure while charging/discharging, temperature is extreme, or leads are long/thin, readings can drift.

Engineer’s tip: Use voltage as a trend indicator. For accurate SOC over time, add a shunt-based battery monitor.

How to Measure Battery Voltage Correctly (for Useful SOC Estimates)

  • Rest before testing: Stop charge/discharge and let the battery rest 30–60 min (2 hrs is ideal) to approach open-circuit voltage.

  • Probe close to the posts: Measure near the battery terminals to minimize line drop.

  • Mind the temperature: Charts below assume around 77 °F (25 °C). Cold raises voltage but reduces usable capacity; heat does the opposite.

  • Expect sag under load: Compressors, inverters, and motor loads pull voltage down temporarily. That’s normal internal resistance in action.

Battery Voltage Chart (12V/24V/48V, Rested, ~77 °F) — LiFePO4 & AGM/Gel

A. LiFePO4 (Nominal 12.8V / 25.6V / 51.2V)
Note: Different brands/BMS may vary. Because the LiFePO4 curve is flat, treat these as rough estimates.

Est. SOC12V (V)24V (V)48V (V)
100%13.6–13.827.2–27.654.4–55.2
90%≈13.4≈26.8≈53.6
80%≈13.3≈26.6≈53.2
70%≈13.25≈26.5≈53.0
60%≈13.2≈26.4≈52.8
50%13.10–13.1526.20–26.3052.40–52.60
40%13.00–13.0526.00–26.1052.00–52.20
30%12.90–12.9525.80–25.9051.60–51.80
20%12.80–12.9025.60–25.8051.20–51.60
10%12.50–12.7025.00–25.4050.00–50.80
0%*BMS cutoff ≈10–11.5≈20–23≈40–46

*“0%” row indicates near/at BMS low-voltage cutoff—avoid deep depletion.

B. AGM/Gel Lead-Acid (Nominal 12V / 24V / 48V)
Note: Chemistry and age change the curve; treat as typical ranges.

Est. SOC12V (V)24V (V)48V (V)
100%12.7–12.925.4–25.850.8–51.6
90%≈12.6≈25.2≈50.4
80%≈12.5≈25.0≈50.0
70%≈12.4≈24.8≈49.6
60%12.3–12.424.6–24.849.2–49.6
50%12.2–12.324.4–24.648.8–49.2
40%≈12.1≈24.2≈48.4
30%≈12.0≈24.0≈48.0
20%≈11.9≈23.8≈47.6
10%≈11.8≈23.6≈47.2
0%≈11.6 or lower≈23.2 or lower≈46.4 or lower

Fast conversions:

  • 24V ≈ 2 × 12V, 48V ≈ 4 × 12V

  • Wh = V × Ah

  • For the same Ah, higher system voltage = lower current & wire loss, better for long runs and higher-power inverters.

Charging Setpoints Quick Guide (Follow Your Battery Maker First)

LiFePO4 (12V example)

  • Bulk/Absorption: 14.2–14.6 V (24V: 28.4–29.2 V; 48V: 56.8–58.4 V)

  • Float (optional): 13.4–13.6 V; many brands recommend low/disabled float

  • No Equalize; respect low-temp charge limits (0 °C/32 °F and below = restricted/avoid)

AGM/Gel (12V example)

  • Bulk/Absorption: 14.2–14.8 V (brand-specific)

  • Float: 13.5–13.8 V

  • Equalize: Only if the model supports it; follow the manual closely.

Engineer’s tip: If your array sees patchy shade or shifting angles, use multiple MPPT inputs and shade-tolerant panel architectures to keep charging steady. Continuous micro-cycling near low SOC accelerates wear—stable charging helps longevity.

Turn Numbers into a System: RV & Off-Grid Design the Smart Way

1) RV Systems (12V/24V DC bus are most common)

  • Loads: Compressor fridge, lights, water pump, fans, electronics, occasional inverter use.

  • Why shading matters: Roofs have vents, AC shrouds, antennas, racks—all cause partial shade that can tank output on conventional strings.

  • Sungold fit (real-world RV roofs):

    • PA621 Anti-Shade Flexible Panels — Segmented strings + robust bypass paths help prevent one shaded patch from collapsing the whole module. Ideal around skylights/antenna shadows.

    • PA219 Lightweight Flexible Panels — Conform to curves and narrow strips to use every inch of roof.

    • TF Walkable Flexible Panels — Where foot traffic occurs (service lanes), low-profile and walkable.

    • SGM Rigid Glass Panels — If you prefer rigid frames for wind resistance and classic mounts.

  • Best practices:

    • Break the array into zones (front/center/rear) with separate MPPTs.

    • Match controller setpoints to your battery’s chemistry (see guide above).

    • Route cables short and thick; fuse each branch; use proper roof penetrations with gland fittings.

Explore RV kits: /rv-solar-kits/ and /camping-solar-system/

2) Off-Grid Systems (Choose 12V vs 24V vs 48V by Power Level)

  • Rule of thumb:

    • Up to ~1 kW: 12V can be fine (short runs, modest inverter).

    • ~1–2 kW: 24V cuts current and keeps wiring practical.

    • >2 kW or long cable runs: 48V recommended (lower current, smaller copper, higher inverter efficiency).

  • Array strategy for reliability:

    • Use PA621 where partial shade is likely (trees, poles, building edges).

    • Combine PA219 flexible on curved shelters or constrained surfaces; choose SGM rigid glass for harsh weather and classic rack installs.

    • Split strings across independent MPPTs for morning/evening orientation or east/west faces.

  • Sizing sketch (quick sanity check):

    • Daily energy: Wh/day from your loads list.

    • Peak-sun-hours (PSH) at site (e.g., 4–6).

    • System derate (wiring, temperature, controller, so use η ≈ 0.75–0.8 as a planning factor).

    • Array watts ≈ Wh/day ÷ (PSH × η).

    • Battery Wh ≈ Wh/day × days of autonomy ÷ usable DoD (and adjust for temperature/aging).

Read more off-grid tips: /off-grid-solar-system-guide/

Sungold Panels for Tough, Real-World Conditions

  • PA621 Anti-Shade Architecture: Segmented strings + robust bypass design mean localized shade doesn’t cripple output—perfect for RV roofs, marina docks, wooded off-grid sites.

  • PA219 Lightweight Flexible: Fits curves and tight spaces; great for maximizing roof area where frames won’t fit.

  • TF Walkable Flexible: Low-profile and foot-friendly surface for decks and service lanes.

  • SGM Rigid Glass: Classic framed durability for high wind, snow, and long-life mounting.

  • BXF-PLUS Balcony Kits (for grid-tied micro-generation): For day-time self-use; if you add storage, align voltage with your inverter/charger specs and local codes.

Share your roof sketch (with obstructions), target battery voltage, and preferred inverter/charger. We’ll suggest a zoned array + MPPT mapping and the right charging setpoints in one page.

Troubleshooting Voltage Readings (Before You Panic)

  • Fresh off charge/discharge? You didn’t rest long enough—voltage will be artificially high/low.

  • Reading at the far end of a long cable? That’s line drop; measure at the battery.

  • Cold morning test? Expect higher voltage but less usable capacity.

  • BMS active? Low/high-voltage or temp cutoffs can skew what you see.

  • Old or mismatched batteries? Parallel/series packs with uneven cells make voltage less predictive of SOC.

RV & Off-Grid FAQs

Q1: Can I rely on voltage alone for LiFePO4 SOC?
A: Only for ballpark checks. Add a shunt monitor for real accuracy.

Q2: How low is “too low” on 12V LiFePO4?
A: Around 12.5 V is already quite low at rest. Near 12.0 V you’re skirting BMS cutoff—avoid deep depletion.

Q3: Do I need float on LiFePO4?
A: Often low or disabled float is recommended—follow your battery brand’s guidance.

Q4: My fridge kicked on and voltage dropped—normal?
A: Yes. That’s transient sag under load. Rest and re-check for SOC reference.

Q5: 12V vs 24V vs 48V—what should I pick?
A: For bigger inverters/longer runs, go higher voltage to cut current and cable loss (24V/48V).

Author picture

Founded in 2008, Shenzhen Sungold Solar Co., Ltd. has always led the way with high-performance photovoltaic modules that can handle harsh environments.Sungold has developed a wide range of adapted products for RVs, yachts, outdoor applications, balcony systems and camping.

Share:

More Posts

Send Us A Message

Subscribe to our Newsletter

SunGold
With advanced technology and professional R&D, Sungold Solar has designed a large number of robust and reliable solar products to power your load.

Signup for Newsletters

Would you like to receive exclusive emails with special offers and information about new products? Then subscribe to our newsletter!

    Scroll to Top